Message:

Serial Port: split single byte port and baud into two bytes, taking advantage of the two bytes in DPT_SERIAL, which supports more serial baud rates and in particular fixed a bug where a 4x client machine couldn't talk to a 115.2K server machine. This is a wide change, touching lots of files, but most are shallow changes. DetectPrint.asm took the most significant changes, now it calculates the baud rate to display instead of using characters provided by the Configurator. The Configurator now has a new menu flag, FLG_MENUITEM_CHOICESTRINGS, for specifying that values are not linear and they should be lookedup rather than indexed. Finally, another important bug fixed here is that in some error cases, the serial port code could get into an infinite loop waiting ont the hardware; now it has a timeout.

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/XTIDE_Universal_BIOS/Src/Device/Serial/SerialDPT.asm

    r226 r233  
    1717SerialDPT_Finalize:
    1818        or      byte [di+DPT.bFlagsHigh], FLGH_DPT_SERIAL_DEVICE
    19         mov     al, [RAMVARS.xlateVars+XLATEVARS.bLastSerial]
    20         mov     byte [di+DPT_SERIAL.bSerialPortAndBaud], al
     19        mov     ax, [es:si+ATA6.wVendor]
     20        mov     word [di+DPT_SERIAL.wSerialPortAndBaud], ax
    2121        ret
    2222