Changeset 567 in xtideuniversalbios for trunk/XTIDE_Universal_BIOS/Inc/ATA_ID.inc


Ignore:
Timestamp:
May 26, 2014, 1:25:15 PM (10 years ago)
Author:
krille_n_@…
google:author:
krille_n_@hotmail.com
Message:

Changes:

  • Renamed MODULE_FEATURE_SETS to MODULE_POWER_MANAGEMENT.
  • Renamed MODULE_VERY_LATE_INITIALIZATION to MODULE_VERY_LATE_INIT and removed it from the official builds.
  • Removed the code that skips detection of slave drives on XT-CF controllers since slave drives can be used with Lo-tech ISA CompactFlash boards.
  • Added autodetection of the SVC ADP50L controller to XTIDECFG.
  • The autodetection of XT-CF controllers now requires MODULE_8BIT_IDE_ADVANCED in the loaded BIOS.
  • Fixed a bug in XTIDECFG from r502 where the "Base (cmd block) address" menu option would be displayed when a serial device was selected as the IDE controller.
  • XTIDECFG would display the "Enable interrupt" menu option for the XTIDE r1 but not for the XTIDE r2. It's now displayed for both controller types.
  • Disabled the "Internal Write Cache" menu option in the Master/Slave Drive menus for serial device type drives.
  • Optimizations and other fixes.
File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/XTIDE_Universal_BIOS/Inc/ATA_ID.inc

    r526 r567  
    8686    .strModel   resb 40 ; 27...46F, Model number (40 ASCII characters, 0000h=not specified)
    8787    .bBlckSize  resb 1  ; 47[0-7]F, Maximum number of sectors that can be transferred
    88                         ;          per interrupt on read and write multiple commands
    89                         ;          (00h=Read/write multiple commands not implemented)
     88                        ;           per interrupt on read and write multiple commands
     89                        ;           (00h=Read/write multiple commands not implemented)
    9090                resb 1  ; 47[8-15]X
    9191    .wDWIO      resw 1  ; 48F, Can perform doubleword I/O (boolean)
     
    106106    ; Words 59-63 are always valid
    107107    .bBlockSel  resb 1  ; 59[0-7]V, Current setting for number of sectors that
    108                         ;           can be transferred per interrupt on R/W multiple command
     108                        ;           can be transferred per interrupt on R/W multiple command
    109109    .bBlockFlgs resb 1  ; 59[8-15]VR, bit 0 set if Multiple sector setting is valid
    110110    .dwLBACnt   resd 1  ; 60...61F, Total number of user addressable sectors (LBA mode only)
     
    168168    .strModel   resb 40 ; 27...46F, Model number (40 ASCII characters, 0000h=not specified)
    169169    .bBlckSize  resb 1  ; 47[0-7]F, Maximum number of sectors that can be transferred
    170                         ;          per interrupt on read and write multiple commands
    171                         ;          (00h=Read/write multiple commands not implemented)
     170                        ;           per interrupt on read and write multiple commands
     171                        ;           (00h=Read/write multiple commands not implemented)
    172172                resb 1  ; 47[8-15]X
    173173                resw 1  ; 48R
     
    188188    ; Words 59-63 are always valid
    189189    .bBlockSel  resb 1  ; 59[0-7]V, Current setting for number of sectors that
    190                         ;           can be transferred per interrupt on R/W multiple command
     190                        ;           can be transferred per interrupt on R/W multiple command
    191191    .bBlockFlgs resb 1  ; 59[8-15]VR, bit 0 set if Multiple sector setting is valid
    192192    .dwLBACnt   resd 1  ; 60...61F, Total number of user addressable sectors (LBA mode only)
     
    253253    .strModel   resb 40 ; 27...46F, Model number (40 ASCII characters, 0000h=not specified)
    254254    .bBlckSize  resb 1  ; 47[0-7]F, Maximum number of sectors that can be transferred
    255                         ;           per interrupt on read and write multiple commands
    256                         ;           (00h=Read/write multiple commands not implemented)
     255                        ;           per interrupt on read and write multiple commands
     256                        ;           (00h=Read/write multiple commands not implemented)
    257257                resb 1  ; 47[8-15]F, 80h
    258258                resw 1  ; 48R
     
    271271    ; Words 59-63 are always valid
    272272    .bBlockSel  resb 1  ; 59[0-7]V, Current setting for number of sectors that
    273                         ;           can be transferred per interrupt on R/W multiple command
     273                        ;           can be transferred per interrupt on R/W multiple command
    274274    .bBlockFlgs resb 1  ; 59[8-15]VR, bit 0 set if Multiple sector setting is valid
    275275    .dwLBACnt   resd 1  ; 60...61F, Total number of user addressable sectors (LBA-28)